Z23-2 set
Shielding Tent (900 x 500 x 650) mm
Short description
The Z23-2 shielding tent has a higher working space than the Z23-1 shielding tent. Therefore, larger devices under test or measuring devices can be used inside the tent. It allows for shielding of the measurement set-up against external RF fields or for shielding the measuring devices, e.g. during ESD tests. From the front, the tent can be easily and quickly opened or closed making access to the device under test or the measuring device always possible. The shielding tent can be folded to the back for even better access to the device under test.
The RF seal of the shielding tent is created with smooth-running magnetic sealing stripes. The shielding tent can be easliy operated by hand. When folded it needs little space and it is easily stored away.
Scope of delivery
Scope of delivery details
-
GP 23
Ground Plate
The GP 23 ground plate is used as reference ground plane for EMC measurements and for shielding devices under test or corresponding measuring devices. The electric connections between the ground plate and the environment are led outward via filter or RF connections to the outside. Power supply c…
-
BZ 23-2
Shielding Material
The shielding cover consists of a conductive fabric material. It is pulled over the tent poles, which are inserted into the GP 23 ground plate. Doing so a shielded room is created, which is suitable for measurements during development of electronic assemblies or larger devices. From the front, the …
-
ZG 23-1
Tent Poles
These metal tent poles are designed to be a base frame for the shielding cover and are inserted into the GP 23 ground plane. It can be easily folded and needs little space for storage.
-
ZGA 23-2
Tent Poles Adapter
The tent poles adapters are needed to adjust the ZG 23 tent poles to the Z23-2 shielding tent with a higher working space. Both adapters are inserted into both rear axes.